2500kVA 33 or 34.5kV Dry-type Distribution Transformer

NPC Electric's dry type transformer is made with vacuum,foil type coil winding machinese,and silicion steel sheets shearing equipment import from Gerorg's,the technology brought from Germany.The technical specifiacation is totaly reached IEC,ANSI,IEEE,UL etc international standards.

 

Product Attributes

 

Model No. :    2500kVA 33kV or 34.5kV
Brand:    NPC ELECTRIC
Application :    Indoor,Construction building
Phase :    Three or single
Coil :    Core-type Transformer
Cooling Method :    AN/AF
Certification :    ISO,UL,IEEE,KEMA,CE
Usage :    
Frequency Characteristics :    50 or 60Hz
Winding Type :    Two-winding Transformer
Standard :    IEC/ANSI/IEEE/CSA or Customized as the client's request

 

Supply Ability & Additional Information

 

Packaging :    Wooden  Packing 
Productivity :    1000sets/month
Transportation :    By sea,truck or train
Place of Origin :    China
Supply Ability :    High
Certificate :    ISO,UL,IEEE,KEMA,CE
HS Code :    85043490
Port :    Qingdao or Shanghai Port
Payment Type :    L/C,T/T
Incoterm :    FOB,CFR,CIF etc

 

Packaging & Delivery

 

Selling Units:     Set/Sets
Package Type:   Wooden Packing

 

Part I: Product Overview For 2500kVA, 33 or 34.5kV      Dry-type Transformer

NPC Electric's dry type transformer is made with vacuum,foil type coil winding machinese,and silicion steel sheets shearing equipment import from Gerorg's,the technology brought from Germany.The technical specifiacation is totaly reached IEC,ANSI,IEEE,UL etc international standards.

Part II: Product Features

1.  Low-noise & Low-loss:

a)  Transformer noise comes from the core. The core is made of high quality cold-rolled grain-oriented silicon steel sheet. The lamination sheets are produced by automatic step-lap core lamination line from GEORG, Germany. Such method improves the distribution of magnetic circuit and result in lowering the noise level.

b)  The transformer adopts the high quality silicon steel sheet whose low magnetic density stays away from its saturation point and decreases the harmonic in the core, and lowers the noise and no-load loss of the transformer.

c)  All parts used for clamping apply silicon rubber and flexible elements as buffers in order to reduce the amplitude and noise of components, while the surface of core is solidifying treated, which plays a role of sound proof.

2.  Non-flammable, no pollution to environment

a)   Solid electrical insulation composed of high quality resin could provide with high electrical strength (breakdown voltage≥34kv/mm) and partial discharge can be controlled in the range of ≤5pC.

b)   As the composite materials resin used in dry-type transformer generate very little heat when in combustion (about 65ml/kg). The transformer has the feature of fire-retardant and self-extinguishing, so no arc will occur because of short circuit and no toxic or harmful smoke or dusts will be produced at high temperature.

c)  The coil is free of moisture and core is soliditying treated. The transformer can be in continuous reliable operation in circumstance of 100% relative humidity, and no need to interrupt its service to eliminate moisture.

d)  Dry type transformer also has great advantages such as strong overload capability, good thermal stability, compact size, light weight, easy installation; maintenance-free and so on Dry type transformer covers wide fields of high-rise buildings, commercial centers, airports, stations, ports, subway, factories and underground power distribution stations.

3.  Cooling method:

Cooling method of dry type transformer is divided into air natural cooling (AN) and air forced cooling (AF). Under the normal conditions, when transformer under air natural cooling(AN) it can output 100% rated capacity continuously When transformer under air forced cooling (AF), its output capacity can be increased by 30% which is suitable for all kinds of emergency, overload or intermittent load operation.   

      4.  Temperature control system:

Temperature control system consists of temperature controller and Pt100 temperature sensor located at the hottest point of transformer Temperature controller has function of temperature display and control of each phase. It will give off trip coil temperature is over limited. Under air forced cooling condition, the temperature controller can automatically start or stop fans according to the winding temperature. The temperature monitoring of windings and core, 4-20mA analog output or RS485 computer communication can be provided according to kinds of requests from clients to meet the need of modern electric power operation automation management.

Part III: Product Main Parameter

Capacity

(kV*A)

Model

No-load Loss

(kW)

Load Loss

(kW) 120oC

No Load Current (%)

Short-circuit Impedance (%)

Total Weight

(kg)

Dimensions

LxWxH (mm)

Enclosure dimensions

LxWxH (mm)

Gauge Distance

DxE (mm)

2500

SC10-2500

4.450

21.8

0.75

6.0

7550

2300x1100x2130

3000x2000x2700

1070x820

SC11-2500

4.010

21.8

0.75

6.0

7580

2300x1100x2130

3000x2000x2700

1070x820

SC13-2500

3.560

21.8

0.75

6.0

7600

2300x1100x2130

3000x2000x2700

1070x820

SCBH15-2500

3.560

19.6

0.75

6.0

7630

2400x1100x2230

3000x2000x2700

1070x820

Part IV: Outline Drawing

 

Packing Details and Loading Containter:

 

  • Payment
    L/C,T/T
  • Incoterm
    FOB,CFR,CIF,etc
  • Min. Order
    1 Set/Sets
  • Transportation
    By Sea,Truck,Train
  • Port
    Qingdao,Shanghai Port
Contact Now