RFOU 8.7/15kV 1x300mm2 EPR/TCWB/EVA Flexible Rubber MV Power Cable

Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

Application
    Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

 

Applicable Standard

    IEC 60092-354 

    NEK 606-2016

 

Material

    Insulation: EPR, IEC 60092-360

    Sheath: SHF2, IEC 60092-360

    Flame retardant: IEC 60332-3-22, Cat.A

    Fire resistance: IEC 60331-21

    Halogen free properties: IEC 60754-1,2 & IEC 60684-2

    Low smoke properties: IEC 61034-1,2

    Sunlight resistance: UL 1581

    Cold properties (option): CSA C22.2 No.03 (Bending : -40C, Impact : -35C)

    Oil/Mud resistance (option): NEK 606-2016 (Category a, b, c, d)


Cable Construction

    Construction Details

    Conductor: Circular tinned stranded copper as per IEC 60228, Class 2

    Conductor screen: Semi-conducting tape and Semi-conducting compound

    Insulation: Halogen Free Ethylene Propylene Rubber

    Insulation screen: Semi-conducting compound and Semi-conducting tape

    Metallic screen: Tinned copper wire braid as per IEC 60092-354

    Fire proof layer: Mica glass tape and Silicon glass tape

    Cabling (with filler)

    Bedding (Fire Block): Halogen free compound

    Inner sheath: Halogen free thermosetting compound as per IEC 60092-360, SHF2

    Armour: Tinned copper wire braid as per IEC 60092-354

    RFCU-FIRE RESISTANT (option): Galvanized steel wire braid as per IEC 60092-354

    Outer sheath: Halogen

 

Dimension Characteristics

Number   of Elements Cross section core mm² Electrical Cross section braid   mm² Conductor Diameter mm Insulation Thickness mm Thickness Inner Covering mm Diameter Inner Covering mm Diameter Braid Wire mm Mechanical cross-section of the   braid mm² Thickness Outer Sheath mm Diameter Outer Sheath mm Weight of Cable Approx. (kg/km)
1 25 20 6.5 4.5 1.0 22.0±1.0 0.4 35 1.8 28.0±1.5 1370
1 35 20 7.4 4.5 1.0 23.0±1.5 0.4 27.1 1.8 29.0±1.5 1500
1 50 20 8.8 4.5 1.0 24.0±1.5 0.4 27.1 1.9 30.5±.5 1700
1 70 20 10.3 4.5 1.0 26.0±1.5 0.4 27.1 1.9 32.0±1.5 2000
1 95 20 12.1 4.5 1.2 28.0±1.5 0.4 31.7 2.0 34.5±2.0 2450
1 120 20 13.6 4.5 1.2 29.5±1.5 0.4 31.7 2.0 36.0±2.0 2700
1 150 20 15.1 4.5 1.2 31.0±1.5 0.4 31.7 2.1 38.0±2.0 3000
1 185 20 16.8 4.5 1.2 33.0±1.5 0.4 31.7 2.2 39.5±2.5 3500
1 240 25 19.1 4.5 1.2 35.0±1.5 0.4 36.2 2.3 42.0±2.5 4300
1 300 29 21.5 4.5 1.2 37.5±1.5 0.4 40.7 2.4 44.5±2.5 5000
1 400 30 25.6 4.5 1.5 42.0±2.0 0.4 49.8 2.6

 

 

  • Brand
    NPC CABLE