12500kVA 33kV 3-phase 2-winding Power Transformer with OCTC
Product Attributes
Supply Ability & Additional Information
Packaging & Delivery
Part I: Product Overview for 12500kVA 33Kv Power Transformer With Octc
12500kVA 33kV high quality oil immersed Power Transformer with Off-circuit tap changer has Optimized Design using advanced technologies, in order to offer low noise, low partial discharge, high short circuit withstand capability. Advanced design software are used for electromagnetic calculation and design of transformer, while 3-D, 2-D CAD software for structural design ensure sufficient safety margin during short circuit period. This is based on in-depth theoretical and experimental studies on magnetic, thermal, mechanical strength and short circuit strength. To ensure reliability of the transformer, the insulation is decided based on calculation on main and vertical insulation. The accurate calculation of the electric field distribution in inner coils will ensure voltage gradient and at coil end it will ensure lower partial discharge.
Part II: Product Features
1. Potential distribution is effectively improved by application of software to calculate the impact and gradient potential distribution. The potential calculation is also done between various parts of the coil including between the coil and coil and earthing.
2. Low loss: Magnetic flux leakage calculation and corresponding measures to effectively reduce the stray loss, and in the meantime effectively prevent local overheating and lower temperature rise of winding hot spots. The electromagnetic optimizing design software is applied to optimize the core and winding design.
3. High resistance to short-circuit capacity: Apply transformer resistance to short-circuit capacity accounting software to design HV winding and LV winding. HV winding will be designed as central outlet, up and down parallel connection with axial oil path; the regulating winding will be designed as central outlet in the middle of HV winding with up and down parallel connection to improve transformer short-circuit resistance.
4. Low partial discharge, extend Transformer Service life.
(1) Analyze calculation of electric field to improve the electric field concentrated region.
(2) The way of vacuum oil filling will effectively prevent the formation of air bubbles inside the transformer and insulation parts to reduce partial discharge.
5. Low noise: Lower the noise level by choosing high quality steel core material; right flux density and the self-vibration frequency of the core; application of high resistance to short-circuit of the body structure; and improving the connection method of tank and active part.
6. Low temperature rise: Apply reasonable oil flow distribution structure by calculation of oil flow distribution; reduce the winding hot spot temperature rise and the average temperature rise in order to increase overload capacity of each part, extend the life of transformer.
Part III: Product Main Parameter
Capacity (kV*A) |
Model |
Vector Group |
No-load Loss (kW) |
Load Loss (kW) |
No Load Current (%) |
Short-circuit Impedance (%) |
Weight(kg) |
Dimensions |
Gauge (mm) |
|
Oil |
Total |
LxWxH (mm) |
||||||||
12500 |
S11-12500/33 |
YNd11 |
10.0 |
53.8 |
0.30 |
8.0 |
4280 |
21000 |
3290x3680x3640 |
1475x1475 |
S13-12500/33 |
8.00 |
Part IV: Outline Drawing
-
PaymentL/C,T/T
-
IncotermFOB,CFR,CIF,etc
-
Min. Order1 Set/Sets
-
TransportationBy Sea,Truck,Train
-
PortQingdao,Shanghai Port