500kVA Oil Immersed Transformer
- Primary Voltage Ratings 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2, 24.94, 26.25, 33 or others
- Secondary Voltage Ratings 480/277V, 400/230V, 380/220V or customized
- H.V. Tap Range ± 2×2.5% HV taps or others
- Type Oil immersed distribution transformer
- BIL 30/95kV
- Standards IEEE, ANSI, NEMA, IEC
- Application Industrial and Commercial Power Distribution Systems
- Power Rating 500kVA
- Certificate UL ,ISO ,CE
- Cooling Method ONAN, ONAN/ONAF, KNAN, KNAN/KNAF
- Oil Mineral Oil or FR3
- Opeartion Step Down & Step Up
Technical Specifications
Technical Specifications | ||
Rated Power | 500 kVA | |
Rating Primary Voltage | 2.4 - 34.5kV | |
Secondary Voltage | 480/277V 400/230V 380/220V Customized |
|
Frequency | 50/60Hz | |
Vector Group | Dyn11, Yyn0, Dyn5 | |
Winding Material | Aluminum/Copper | |
Efficiency | As IEEE, Doe 2016, CAS Std or Customized | |
Impedance Voltage | Nominal 2% or Customized 1.1 - 5.75% | |
Altitude | ≤1,000m or Customized | |
Color | ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc | |
Tank material | Mild Steel, 304 Stainless Steel | |
Insulating Oil Weight | 575 kg | |
Total Weight | 2500 kg | |
Outline Dimensions(L×W×H)in. | 2000 × 1500 × 2000(mm) |
HV Bushing |
LV Bushing |
Tap changer |
Oil level gauge |
Oil temperature indicator |
Pressure relief device |
Pressure vacuum gauge |
Lifting hook for complete transformer |
Name plate |
Radiators |
Oil upper filtering valve |
Oil drain valve with 3/8" sampler |
Customization Optional
Packing and Shipping
The transformer is fixed on a sturdy wooden pallet to maintain stability and prevent tilting or displacement. Rubber shock-absorbing pads are used at key stress-bearing parts to reduce the impact of vibration during transportation. The outside of the transformer is covered with moisture-proof and rust-proof plastic film to avoid being affected by the external environment.
The outside is packed with high-strength wooden boxes or steel frame structures to prevent the transformer from being hit during long-distance transportation. Indicators such as "lifting point", "no tilting", and "fragile" are marked on the outside of the package to ensure correct loading and unloading. The transformer is equipped with a silicone desiccant to prevent moisture from affecting its performance during transportation.
The accessories, such as the bushing, oil pillow, and thermostat of the transformer, are packed separately and placed in a special wooden box to avoid damage. The nameplate, technical manual, test report, certificate of conformity, and other documents are packed in a waterproof document bag and included with the goods.
NPC ELECTRIC's 500kVA three-phase oil-immersed transformer is packaged in a sturdy and protective design, combined with efficient logistics and transportation, to ensure that the equipment arrives at the customer site intact and safe.


Manufacturer Test

Progress Test
NPC ELECTRIC’s three-phase oil-immersed transformers are subject to rigorous process testing during the production process to ensure quality and performance. First, raw materials such as silicon steel sheets and copper windings are subject to factory inspection to ensure compliance with technical standards. After the windings and cores are assembled, DC resistance tests and insulation withstand voltage tests are carried out to detect electrical performance. Finished transformers are subject to induced withstand voltage and partial discharge tests to verify the reliability of the insulation system. Load loss and no-load loss tests are used to evaluate the operating efficiency and energy consumption level of the transformer. Finally, after the transformer is oil-treated and sealed, it undergoes factory testing to ensure its safety and stability under various operating conditions.

Design Tests
All transformer will be test after finished the production, test items as below:
♦ Insulation Power Factor
♦ Ratio, Polarity, and Phase Relation
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Polarity, 1-Ph / Phase Relation, 3-Ph (Rated Voltage)
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Applied Voltage
♦ Induced Voltage
♦ Lightning Impulse
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise
♦ Dielectric Withstand (Hipot)

Transformer Factory Acceptance Test
The Factory Acceptance Test (FAT) of 500 kVA three-phase oil-immersed transformers is designed to ensure that the product meets technical standards and customer requirements. First, a visual inspection is carried out to confirm that the transformer is structurally intact, clearly marked, and free of mechanical damage. This is followed by a winding DC resistance test to detect whether the winding resistance meets the design standards. The insulation withstand voltage test is used to verify the insulation strength of the transformer to ensure its safety under high-voltage operation. The induction withstand voltage test is used to check the electrical performance of the core and windings to prevent potential insulation failures. The partial discharge test is used to detect insulation defects inside the transformer to ensure long-term reliable operation. The no-load loss and load loss tests evaluate the energy efficiency of the transformer to ensure that the specified performance parameters are met. The ratio and polarity test are used to verify the voltage conversion capability and phase sequence correctness of the transformer. The temperature rise test simulates the actual operating environment to ensure that the temperature change of the transformer under rated load is within a safe range. Finally, an oil sample analysis is carried out to test the insulation properties and moisture content of the transformer oil to ensure that the quality of the oil meets the standards.
Routine Test - DC Insulation Resistance Test
Voltage source (usually 500V, 1000V, 2500V, or customized according to customer requirements)
Temperature and humidity meter (used to record the ambient temperature and humidity during the test to ensure that the test conditions meet the standard requirements.)
Perform the test under suitable environmental conditions. It is recommended to have a relative humidity below 75%, no rain, and a temperature range of 20-30°C to avoid moisture or temperature fluctuations affecting the test results.
Connect an insulation resistance tester to the high voltage terminal of the device under test and to ground.
Apply Test Voltage:
Select an appropriate test voltage based on the rated voltage of the equipment .
Insulation resistance value (MΩ)
Applied voltage
Ambient temperature and humidity during testing
500 MΩ ≤ Insulation resistance < 1000 MΩ (good)
100 MΩ ≤ Insulation resistance < 500 MΩ
Insulation resistance < 100 MΩ

Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What is a Transformer?A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
-
What are the main uses of a transformer?The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
-
Do you have UL listed?Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.