50kVA Oil Immersed Transformer
- Primary Voltage Ratings 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2, 24.94, 26.25, 33 or others
- Secondary Voltage Ratings 480/277V, 400/230V, 380/220V or customized
- H.V. Tap Range ± 2×2.5% HV taps or others
- Type Oil immersed distribution transformer
- BIL 30/95kV
- Standards IEEE, ANSI, NEMA, IEC, GB
- Application Power Distribution Substations, Renewable Energy Systems, Residential Areas, Temporary Power Supply Systems, Utilities
- Power Rating 50kVA
- Certificate UL , CESI , IEEE
- Cooling Method ONAN, ONAN/ONAF, KNAN, KNAN/KNAF
- Oil Mineral Oil or FR3
- Opeartion Step Down & Step Up
Technical Specifications
Technical Specifications | ||
Rated Power | 50 kVA | |
Rating Primary Voltage | 2.4 - 34.5kV | |
Secondary Voltage | 480/277V 400/230V 380/220V Customized |
|
Frequency | 50/60Hz | |
Vector Group | Dyn11, Yyn0, Dyn5 | |
Winding Material | Aluminum/Copper | |
Efficiency | As IEEE, Doe 2016, CAS Std or Customized | |
Impedance Voltage | Nominal 2% or Customized 1.1 - 5.75% | |
Altitude | ≤1,000m or Customized | |
Color | ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc | |
Tank material | Mild Steel, 304 Stainless Steel | |
Insulating Oil Weight | 75 kg | |
Total Weight | 335 kg | |
Outline Dimensions(L×W×H)in. | 760 × 640 × 920(mm) |
HV Bushing |
LV Bushing |
Tap changer |
Oil level gauge |
Oil temperature indicator |
Pressure relief device |
Pressure vacuum gauge |
Lifting hook for complete transformer |
Name plate |
Radiators |
Oil upper filtering valve |
Oil drain valve with 3/8" sampler |
Customization Optional
Packing and Shipping
For this purpose, the packaging and transportation process of 50kVA three-phase oil-immersed transformers is carefully designed to ensure that the transformers are fully protected throughout the transportation process and arrive safely at the destination. First, the transformers will be placed in sturdy wooden boxes or wooden pallets for packaging. The packaging materials are treated with anti-corrosion to ensure moisture-proof, corrosion-proof, and can withstand the pressure of long-distance transportation. In order to reduce the vibration and impact that may occur during transportation, the transformers will be wrapped with materials such as shock pads, bubble film, plastic film, etc., and ensure that the transformers are firmly fixed in the packaging to prevent any displacement or collision. Since the transformer adopts an oil-immersed design, special attention should be paid to the sealing and oil level of the oil tank during packaging to ensure that the insulating oil will not leak during transportation. Clear markings will be affixed to the outside of the packaging, including "fragile", "moisture-proof", "keep dry" and "center of gravity mark", etc., to remind the transport personnel to pay attention to the requirements of handling and storage. Depending on the transportation destination and conditions, the transformers are usually transported by land, sea or rail transportation to ensure that the most appropriate means of transportation is selected. For international transportation, relevant customs documents such as commercial invoices, packing lists and export permits are also required to ensure smooth customs clearance and meet the import requirements of the destination country. After arriving at the destination, the transformer will be unloaded and visually inspected to ensure that the packaging is intact and the equipment is not damaged.
Through this series of carefully arranged packaging and transportation steps, it is ensured that the 50kVA three-phase oil-immersed transformer can be safely and smoothly delivered to the customer and is ready for use.


Manufacturer Test

Progress Test
NPC Electric manufactures three-phase oil-immersed transformers the strict quality control. The Progress Test of a 50kVA three-phase oil-immersed transformer includes a series of rigorous inspections and tests to ensure that the performance of the transformer meets the design requirements and relevant standards.
The test content usually includes: winding resistance test, insulation resistance test, short-circuit impedance and load loss test, no-load loss test, and dielectric strength test, etc., to ensure that the electrical performance of the transformer meets the predetermined requirements.
In addition, the oil of the transformer will also be tested to check the quality and insulation strength of its insulating oil.
The Progress Test also includes an inspection of the external structure of the transformer, such as the sealing of the oil tank, the effectiveness of the pressure relief device, and the cooling system, to ensure that it meets safety standards.
During these tests, a temperature rise test is also performed to verify whether the heat dissipation effect and temperature control of the transformer under normal working load meet the requirements.
These tests ensure the reliability and long-term stable operation of the transformer.

Design Tests
All transformer will be test after finished the production, test items as below:
♦ Insulation Power Factor
♦ Ratio, Polarity, and Phase Relation
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Polarity, 1-Ph / Phase Relation, 3-Ph (Rated Voltage)
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Applied Voltage
♦ Induced Voltage
♦ Lightning Impulse
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise
♦ Dielectric Withstand (Hipot)

Transformer Factory Acceptance Test
NPC Electric will have tests made for quality control by the manufacturer on every device or representative samples, or on parts or materials as required, to verify during production that the product meets the design specifications.
The Factory Acceptance Test (FAT) of a 50kVA three-phase oil-immersed transformer is a comprehensive inspection process to ensure that the transformer meets the design requirements, technical standards, and quality specifications. The test usually includes several key items. First, a winding resistance test is performed to verify whether the resistance value of the winding meets the design specifications. Next, an insulation resistance test is performed to ensure the safety of the insulation system of each part of the transformer to prevent short circuits and leakage. The temperature rise test simulates the operating temperature of the transformer under rated load to ensure that it will not fail due to overheating during long-term operation. Oil level and oil quality inspection ensure that the transformer's insulating oil is at a normal oil level and that the oil quality meets relevant standards. Finally, external structure inspection is performed, including the tightness of the oil tank, the pressure relief device, the effectiveness of the cooling system, and the safety of mechanical components. Through these tests, it is ensured that the transformer can meet all performance requirements before leaving the factory, and has good safety, reliability, and long-term operation stability.
Routine Test - Insulation Power Factor

Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What is a Transformer?A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
-
What are the main uses of a transformer?The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
-
Do you have UL listed?Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.