x
2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable
2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable

2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable

2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable is designed for reliable secondary overhead power delivery from utility distribution lines to residential and light commercial service entrances. The duplex construction consists of two concentrically stranded aluminum conductors, commonly used as a phase conductor and a neutral messenger, providing both electrical transmission and mechanical support. The No. 2 Schnauzer conductor size offers a practical balance between current-carrying capacity and tensile strength, ensuring controlled sag for short- to medium-span service drop installations. Aluminum conductors provide lightweight handling, excellent corrosion resistance, and simplified installation in outdoor environments. Manufactured in accordance with ASTM standards and utility specifications, the 2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable delivers uniform stranding, stable conductivity, and dependable long-term performance. It is widely selected by utilities and contractors seeking a durable, cost-effective solution for overhead service drop applications.
Construction
Technical Specifications
Quality Control
Application

Construction

2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Constrution
2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

Phase Conductor

Stranded compacted circular aluminum

Insulation

XLPE(UV-resistant)

Messenger Conductor

AAC/AAAC/ACSR

Application

Aluminum Conductor Duplex Overhead Service Drop Cable is designed for use to supply 120-volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 90°C maximum.

Application Type

2 schnauzer aluminium overhead cables, 2 schnauzer overhead aluminum wire, 2 schnauzer two conductor cable, 2 schnauzer 2 conductor power cable, 2 schnauzer two conductor, 2 schnauzer aluminum drop, 2 schnauzer overhead service drop conductors, 2 schnauzer overhead service conductors.

Product Highlights

Voltage Rating: 600V or lower
Max Temperature: 90°C
Conductors: Available with AAC, AAAC, or ACSR messenger conductors

Insulation: XLPE (UV-resistant) for superior weather protection
Aluminum Conductors: 1350-H19 series for enhanced conductivity

Technical Specifications

2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable
2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable
Rated voltage kV 0.6/1
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable
2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Material Test

Raw Material Test

The Raw Material Test is the first quality control step for the 2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable. Incoming aluminum rods are tested for chemical composition, electrical conductivity, tensile strength, and elongation to ensure compliance with specification limits. Surface quality and dimensional accuracy are inspected to prevent defects during wire drawing. Each batch of aluminum material is clearly identified and fully traceable throughout production. Only aluminum materials meeting defined electrical and mechanical requirements are approved for manufacturing, ensuring the finished 2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable achieves consistent performance, durability, and long service life.

2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Process inspection

Process inspection

Process Inspection ensures stable manufacturing quality of the 2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable. During wire drawing, conductor diameter, surface finish, and mechanical consistency are continuously monitored. In the stranding process, precise lay length and balanced tension are applied to achieve proper flexibility and conductor alignment. In-process inspections verify strand compactness, roundness, and structural integrity. These controls ensure the cable meets design requirements for electrical reliability and mechanical durability.

2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Finished Product

Finished Product

The Finished Product Test confirms the final compliance of the 2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable. Electrical resistance testing verifies conductivity performance, while tensile strength and elongation tests confirm mechanical integrity. Additional inspections include conductor diameter measurement, visual surface examination, marking verification, and packaging checks. These tests ensure the cable is safe, compliant, and ready for installation.

Application

Used for overhead service drop connections supplying electricity from utility distribution lines to residential homes, commercial buildings, and light industrial service entrances.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion