AAAC Dog Conductor Cable
- Voltage Rating Up to 33kV (typical)
-
Temperature Rating
Operating: -10°C to +90°C
Short-circuit (5s): up to 250°C
Construction
Conductor
Core
Surface
Manufacturer Standard
Application
Key Features
Excellent electrical conductivity
Superior corrosion resistance, ideal for coastal and industrial environments
Lightweight and easy to install, suitable for long-span overhead lines
Technical Specifications
| Construction characteristics | |
| Type of cable | Dog |
| Type of conductor | Circular, stranded |
| Conductor material | aluminum / Steel Core |
| Conductor flexibility | Class A/AA |
| Conductor shape | Circular non compacted |
| Dimensional characteristics | |
| Conductor cross-section (AWG/KCMIL) | 2 |
| Aluminium cross-section | 33.59 mm² |
| Number of aluminium wires | 6 |
| Diameter of aluminium wires | 2.47 mm |
| Number of steel wires | 1 |
| Diameter of steel wires | 2.47 mm |
| Conductor diameter | 8.01 mm |
| Average geometric radius | 0.00308 m |
| Aluminium content | 92.6 kg/km |
| Steel content | 43.6 kg/km |
| Approximate weight | 136.2 kg/km |
| Conductor cross-section | 39.19 mm² |
| Maximum outer diameter | - mm |
| Nominal outer diameter | 8.01 mm |
| Number of cores | 1 |
| Number of round wires | - |
| Electrical characteristics | |
| Max. DC resistance of the conductor at 20°C | 0.8541 Ohm/km |
| Max. electric resistance AC 60Hz 75°C | 1.102 Ohm/km |
| Inductive reactance | 0.4362 Ohm/km |
| Capacitive reactance | 0.2835 MOhm.km |
| Ampacity | 190.0 A |
| Rated Voltage Uo/U (Um) | - |
| Mechanical characteristics | |
| Rated breaking load (Class A) | 1290 kgf |
| Rated breaking load (Class B) | 1252 kgf |
| Hardness type | 1350-H19 |
| Usage characteristics | |
| Length | 2200 m |
| Reel net weight | 320 kg |
| Packaging | Reel 80/45 |
| Fire resistant | |
| Flame retardant | |
Quality Control
Raw Material Test
Raw Material Test establishes the performance foundation of the AAAC Dog Conductor Cable. Aluminum alloy materials are tested for alloy composition accuracy, conductivity, tensile strength, and elongation. Surface condition and rod uniformity are inspected to prevent defects during wire drawing. All raw materials are verified for compliance with applicable standards and production traceability. Only qualified aluminum alloy inputs proceed to manufacturing, ensuring consistent quality and performance of the AAAC Dog Conductor Cable.
Process inspection
Process Inspection ensures precision manufacturing of the AAAC Dog Conductor Cable. Wire drawing is controlled to achieve consistent diameters and smooth finishes. During stranding, aluminum alloy wires are applied with accurate lay ratios and balanced tension. Continuous inspections confirm concentric construction, strand uniformity, and conductor compactness, ensuring stable electrical and mechanical characteristics throughout production.
Finished Product
Finished Product Test validates the final quality of the AAAC Dog Conductor Cable. Electrical resistance testing confirms current-carrying capacity. Mechanical tests verify tensile strength and elongation performance. Final inspections include dimensional verification, surface quality checks, conductor marking accuracy, and packaging evaluation, ensuring reliable delivery and installation readiness. Dimensional measurement, visual inspection of strand formation, marking verification, and packaging inspection are conducted to ensure the product is ready for safe transportation and installation.
Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.