4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable
4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable

4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable

Introducing the 4 Spaniel Duplex Service Drop Cable, a versatile overhead solution for low-voltage secondary distribution. Built with two 4 AWG aluminum conductors (7-strand) insulated with polyethylene or XLPE and formed into a duplex assembly, it meets ASTM and ICEA requirements for 600V service. The tough insulation offers outstanding protection against UV rays, moisture, tree contact, and abrasion. Compact duplex design provides self-support and easy pulling during installation. The 4 Spaniel Duplex Service Drop Cable supports efficient power transfer with low voltage drop and high durability in extreme temperatures. Popular for its lightweight construction and reduced installation time, it is the go-to choice for electricians and utilities. Widely deployed in housing developments, farm services, and temporary power setups, this cable ensures safe, long-lasting overhead connections from distribution transformers to customer service entrances worldwide.
Construction
Technical Specifications
Quality Control
Application

Construction

4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable Constrution
4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

Phase Conductor

Stranded compacted circular aluminum

Insulation

XLPE(UV-resistant)

Messenger Conductor

AAC/AAAC/ACSR

Application

Aluminum Conductor Duplex Overhead Service Drop Cable is designed for supplying 120-volt aerial service for temporary power at construction sites, as well as for outdoor or street lighting applications. It is rated for use at 600 volts or less, with a maximum conductor operating temperature of 90°C.

Application Type

4 spaniel aluminium overhead cables, 4 spaniel overhead aluminum wire, 4 spaniel two conductor cable, 4 spaniel 2 conductor power cable, 4 spaniel two conductor, 4 spaniel aluminum drop, 4 spaniel overhead service drop conductors, 4 spaniel overhead service conductors.

Technical Specifications

4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable
4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable
Rated voltage kV 0.6/1
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable
4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable Material Test

Raw Material Test

Raw material testing for the 4 Spaniel Duplex Service Drop Cable starts with aluminum certification for electrical grade and mechanical specifications. Conductor wires face resistivity, elongation, and bend tests. Insulation/sheath compounds undergo viscosity, thermal stability, and migration analysis. Carbon black is quantified for UV protection. The structured process: receipt documentation review, random sampling, physical/mechanical testing (tensile, elongation), chemical verification using spectroscopy, accelerated aging/UV trials, and material release decision. This ensures defect-free inputs, providing the base for the 4 Spaniel Duplex Service Drop Cable's conductivity, insulation quality, weather performance, and environmental resistance in overhead duplex applications.

4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable Process inspection

Process inspection

Process inspection during 4 Spaniel Duplex Service Drop Cable production involves multi-point quality assurance. Aluminum conductor forming monitors strand uniformity and surface smoothness. Insulation extrusion ensures adhesion with thickness gauges. Duplex assembly stages check twisting, positioning, and tension. Online spark testing and eccentricity measurement are performed. Critical steps: pre-extrusion compound verification, parameter stabilization, real-time dimension scanning, sampling for uniformity, and defect removal protocols. This multi-stage control maintains the 4 Spaniel Duplex Service Drop Cable's structural precision, reliable insulation, strong duplex bonding, and ASTM/ICEA compliance throughout manufacturing.

4 Spaniel Aluminum Conductor Duplex Overhead Service Drop Cable Finished Product

Finished Product

Completed 4 Spaniel Duplex Service Drop Cable reels face rigorous tests. Key routines: DC resistance, high-potential AC test, thickness checks, and continuity verification. Mechanical endurance via impact, crushing, and pulling tests. Flame propagation and heat shock evaluations follow. The sequential process: conditioning, load/voltage application, timed exposure monitoring, recovery inspection, property re-measurement, and documentation. Additional checks cover ovality and weight. Passing all confirms the 4 Spaniel Duplex Service Drop Cable's mechanical strength, electrical reliability, moisture protection, and suitability for overhead duplex service drops in demanding conditions.

Application

Excellent for overhead duplex connections in new housing projects, renovations, and agricultural buildings. Commonly used for single-phase service from poles to weatherheads requiring lightweight, durable aluminum cables with good weather and mechanical resistance.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.