11/0.4kV 630kVA Oil-Immersed Power Transformer Distribution Type
- Primary Voltage Ratings 35kV, 46kV or others
- Secondary Voltage Ratings 11/0.4kV or others
- H.V. Tap Range ±8×1.25% or others
- Type Oil-immersed power transformer
- BIL 11/0.4kV
- Standards IEEE, ANSI, NEMA, IEC, CE
- Application mining operations, oil & gas facilities
- Power Rating 630kVA
- Certificate UL, CESI, IEEE
- Cooling Method ONAN/ONAF
- Oil Mineral Oil or FR3
- Opeartion Step Down & Step Up
Technical Specifications
| Rated Power | 630kVA | |
| Rating Primary Voltage | 11/0.4kV | |
| Secondary Voltage |
6.6kV 10kV 13.8kV Customized |
|
| Frequency | 50/60Hz | |
| Vector Group | Dyn11, Yyn0, Dyn5 | |
| Winding Material | Aluminum/Copper | |
| Efficiency | As IEEE, Doe 2016, CAS Std or Customized | |
| Impedance Voltage | Nominal 2% or Customized 1.1 - 5.75% | |
| Altitude | ≤1,000m or Customized | |
| Color | ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc | |
| Tank material | Mild Steel, 304 Stainless Steel | |
| HV Bushing |
| LV Bushing |
| Tap changer |
| Oil level gauge |
| Oil temperature indicator |
| Pressure relief device |
| Pressure vacuum gauge |
| Lifting hook for complete transformer |
| Name plate |
| Radiators |
| Oil upper filtering valve |
| Oil drain valve with 3/8" sampler |
Customization Optional
Packing and Shipping
Shipping options are tailored to client needs, offering flexible modes for efficient delivery of this high-efficiency distribution transformer. For domestic shipments, we utilize trusted road freight partners with GPS-tracked vehicles, ensuring timely arrival within 7-14 days depending on location. International orders leverage sea or air freight; containerized ocean shipping in 20ft or 40ft units protects against saltwater exposure, with transit times averaging 20-45 days to major ports worldwide. Air cargo is available for urgent requirements, delivering in 3-7 days but at a premium cost.
Documentation and compliance are integral to our packing and shipping protocol, enhancing SEO visibility for "secure power transformer logistics." Each package comes with detailed manifests, certificates of origin, and test reports to expedite customs processes. We adhere to hazardous material regulations for oil-filled units, using UN-approved labeling and spill-proof seals. Eco-friendly practices include recyclable packing materials where possible, aligning with sustainable shipping trends. Tracking portals allow real-time updates via email or app, keeping clients informed from warehouse dispatch to site delivery, thus optimizing the end-to-end experience for high-efficiency distribution equipment.
Post-shipment support ensures seamless integration of the 11/0.4kV 630kVA transformer upon arrival. Our team provides unpacking guidelines and optional on-site assistance for installation, minimizing downtime. Return policies cover manufacturing defects within 30 days, with reverse logistics arranged at no extra cost. For bulk orders, consolidated shipping reduces expenses and carbon footprint, appealing to environmentally conscious buyers.
Manufacturer Test
Progress Test
Advanced progress testing for this high-efficiency distribution transformer includes tap changer functionality verification, ensuring smooth voltage adjustments without arcing through cycle tests exceeding 10,000 operations. Cooling system efficacy is evaluated by monitoring radiator flow rates and temperature gradients during simulated overloads up to 120% capacity. Final assembly vibration analysis uses accelerometers to confirm structural stability below 5mm/s, preventing operational noise. Environmental stress tests expose the unit to humidity cycles (95% RH) and thermal shocks (-20°C to 80°C) to validate durability. Comprehensive data logging supports traceability, enhancing appeal in searches for "progressive oil-immersed transformer quality assurance," ensuring the 630kVA model meets high-efficiency benchmarks before shipment.
Design Tests
All transformer will be test after finished the production, test items as follows:
♦ Insulation Power Factor
♦ Ratio, Polarity, and Phase Relation
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Polarity, 1-Ph / Phase Relation, 3-Ph (Rated Voltage)
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Applied Voltage
♦ Induced Voltage
♦ Lightning Impulse
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise
♦ Dielectric Withstand (Hipot)
Transformer Factory Acceptance Test
Factory Acceptance Tests (FAT) for the 11/0.4kV 630kVA Oil-Immersed Power Transformer commence with ratio and polarity checks using calibrated voltmeters to confirm accurate voltage transformation and phase alignment. No-load and load loss measurements are conducted at rated frequency, verifying efficiency exceeds 98% with precision wattmeters. Insulation resistance is tested at 5kV DC, ensuring values over 1GΩ for safety in high-efficiency distribution. Short-circuit impedance is evaluated to match specified 5%, using impedance bridges for network compatibility. These tests, witnessed by clients, incorporate SEO-relevant documentation like "high-efficiency transformer FAT protocols," guaranteeing compliance with IEC standards.
Routine Test - Induced Voltage
AC voltage source, commonly 2 kV, 5 kV, 10 kV, or customized according to test requirements.
Environmental thermometer and hygrometer, used to record the temperature and humidity of the environment for appropriate test evaluation.
Check the connection wires and terminals to ensure they are secure and free of contamination.
Test under suitable environmental conditions: relative humidity below 75%, no rain (recommended temperature: 20-30°C).
Connect the test equipment to the appropriate terminals or bushings of the device under test, ensuring that the connections are secure and properly grounded.
Apply Test Voltage:
Select the appropriate induction voltage according to the rated voltage and standard of the equipment.
Induced Voltage
Applied Current
Voltage peak, stability and waveform (waveform analysis)
Any abnormal current or voltage changes during the measurement process.
1% < Inductive voltage ≤ 3% (Good): still within acceptable range.
Inductive voltage > 3% : faulty or not meet safety requirements and requires further analysis and repair.
Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What is a Transformer?A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
-
What are the main uses of a transformer?The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
-
Do you have UL listed?Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.