11kV 1500kVA Zigzag Wiring Earthing Transformer with NGR High Impedance

11kV 1500kVA Zigzag Wiring Earthing Transformer with NGR (High Impedance) is designed to provide a reliable artificial neutral point for medium-voltage power systems where controlled earth fault current is required. Utilizing a zigzag winding configuration, the transformer offers low zero-sequence impedance while maintaining balanced operation during normal conditions. The integrated high-impedance Neutral Grounding Resistor (NGR) effectively limits ground fault current, reducing thermal and mechanical stress on network equipment. This transformer is engineered for stable performance, high fault withstand capability, and long operational life. The robust insulation system and reinforced windings ensure safe operation under fault conditions, while the optimized core design minimizes losses.
Primary Voltage Ratings 34.5/33/24/11kV or others
Secondary Voltage Ratings 480/277V, 400/230V, 380/220V, no LV winding or customized
H.V. Tap Range ± 2×2.5% HV taps or others
Type Earth transformer
BIL 11kV or others
Standards IEEE, ANSI, NEMA, IEC, GB
Application utility substations, industrial plants, and renewable energy systems
Power Rating 1500kVA
Certificate UL ,CESI
Cooling Method ONAN, KNAN
Oil Mineral Oil or FR3
Opeartion Grounding
Technical Specifications
Customization Optional
Packing and Shipping
Manufacturer Test
Routine Testing
Application

Technical Specifications

11kV 1500kVA Zigzag Wiring Earthing Transformer with NGR High Impedance
Technical Specifications
Accessories
Rated Power 1500kVA
Rating Primary Voltage 2.4-34.5kV
Secondary Voltage 480/277V
400/230V
380/220V
Customized
Frequency 50/60Hz
Vector Group ZNd, ZN
Winding Material Aluminum/Copper
Zero-Sequence Impedance Customized
Altitude ≤1,000m or Customized
Color ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized etc
Tank material Mild Steel, 304 Stainless Steel
Insulating Oil Weight 1000 kg
Total Weight 4200 kg
Outline Dimensions(L×W×H)in. 2500×1100×2500(mm)
HV Bushing
LV Bushing
Tap changer
Oil level gauge
Oil temperature indicator
Pressure relief device
CT
Lifting hook for complete transformer
Name plate
Radiators
Oil upper filtering valve
Oil drain valve with 3/8" sampler
Terminal box

Customization Optional

11kV 1500kVA Zigzag Wiring Earthing Transformer with NGR High Impedance
The 11kV 1500kVA Zigzag Earthing Transformer with NGR can be customized to meet a wide range of grounding philosophies and protection schemes. System voltage levels, rated capacity, and zero-sequence impedance can be adjusted to suit specific network requirements. The Neutral Grounding Resistor is configurable in terms of resistance value, thermal rating, and short-time current withstand duration, allowing precise control of earth fault current magnitude. Customers may select copper or aluminum conductors depending on efficiency expectations, thermal margins, and budget considerations. Continuous and intermittent fault duty ratings can also be customized to align with protection relay coordination and clearing times.
Mechanical and environmental customization ensures adaptability to diverse installation environments. The transformer structure can be designed for indoor substations or sheltered outdoor locations. Insulation class, temperature rise limits, and cooling configuration are adjustable to suit ambient temperature and ventilation conditions. Noise-optimized core designs are available for installations near sensitive areas. Optional accessories include temperature monitoring sensors, grounding current indicators, space heaters, and protective enclosures with varying IP ratings. These customization options ensure seamless integration into existing power systems while enhancing safety, reliability, and long-term operational performance.

Packing and Shipping

11kV 1500kVA Zigzag Wiring Earthing Transformer with NGR High Impedance
Packing and shipping of the zigzag earthing transformer are carried out with strict attention to mechanical protection and insulation integrity. Before packing, the transformer undergoes a final inspection to verify assembly accuracy, terminal alignment, and cleanliness. All exposed electrical connections, grounding terminals, and insulation surfaces are covered with protective caps and impact-resistant materials.
The transformer is wrapped using moisture-resistant and dust-proof packaging suitable for dry-type or oil-filled grounding equipment. For extended transportation or export shipments, additional cushioning and vibration-damping layers are applied. The Neutral Grounding Resistor, control panels, and auxiliary components are packed separately in labeled crates to prevent damage and facilitate on-site installation.
The main unit is secured on reinforced wooden or steel pallets designed to support the transformer’s weight and maintain stability during handling. Shock-absorbing pads reduce vibration during road, rail, or sea transport. All wooden packaging materials comply with ISPM 15 international phytosanitary regulations.
Clear lifting instructions, handling symbols, and safety warnings are displayed on the packaging. Complete shipping documentation—including packing lists, factory test reports, installation manuals, and certificates—is provided to ensure smooth customs clearance and site acceptance. This systematic approach ensures the transformer arrives ready for installation and commissioning.
Earth Transformer package
Earth Transformer package mini
32
32 years of industry experience

Manufacturer Test

11kV 1500kVA Zigzag Wiring Earthing Transformer with NGR High Impedance
Earth Transformer Progress Test

Progress Test

An alternative progress testing program emphasizes process monitoring and documentation at each production milestone. Raw materials are tracked from receipt through assembly to ensure specification compliance. Core loss measurements and dimensional checks validate magnetic efficiency before coil installation.

Winding operations are monitored for correct tension, insulation overlap, and structural integrity. Drying cycles and thermal treatments are controlled and recorded. Electrical integrity tests confirm insulation health before enclosure installation.

Final inspections verify mechanical stability, grounding configuration, and accessory installation. Comprehensive records support quality assurance prior to FAT.

Earth Transformer Design Tests

Design Tests

All transformer will be test after finishing the production, test items as follows:
♦ Insulation Power Factor
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Applied Voltage
♦ Induced Voltage
♦ Lightning Impulse
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise

China NPC ELECTRIC

Transformer Factory Acceptance Test

The Factory Acceptance Test validates that the earthing transformer meets contractual and technical requirements. Tests include winding resistance measurement, insulation resistance testing, and impedance verification. Functional tests confirm correct zigzag grounding behavior and NGR performance.

Temperature rise tests verify thermal design, while noise measurements confirm compliance with environmental standards. Visual and dimensional inspections ensure assembly quality. All results are documented in a FAT report for customer approval.

Tests verify high-impedance grounding characteristics, short-time current withstand capability, and insulation strength. Auxiliary devices such as grounding indicators and temperature sensors are functionally tested.

Routine Test - DC Insulation Resistance Test

Purpose of Testing
The purpose of DC insulation resistance testing is to measure the insulation resistance of a device by applying a DC voltage, thereby evaluating the health of the insulation material and the voltage withstand capability of the electrical device. This test helps detect potential insulation aging, moisture or damage, preventing electrical failures in the device.
Testing Equipment
Insulation resistance tester (e.g. Megger, Fluke, Hioki, Klein Tools, etc.)
Voltage source (usually 500V, 1000V, 2500V, or customized according to customer requirements)
Temperature and humidity meter (used to record the ambient temperature and humidity during the test to ensure that the test conditions meet the standard requirements.)
Pre-Test Preparation
Make sure the device is properly grounded and fully discharged to prevent residual charge in the device from affecting the test results.
Perform the test under suitable environmental conditions. It is recommended to have a relative humidity below 75%, no rain, and a temperature range of 20-30°C to avoid moisture or temperature fluctuations affecting the test results.
Test Progress
Connect the Test Instrument:
Connect an insulation resistance tester to the high voltage terminal of the device under test and to ground.
Apply Test Voltage:
Select an appropriate test voltage based on the rated voltage of the equipment .
Measure and Record
Start the test and record the following parameters:
Insulation resistance value (MΩ)
Applied voltage
Ambient temperature and humidity during testing
Temperature Correction
The measured insulation resistance values are corrected to a reference temperature (usually 20°C) for accurate evaluation.
Repeat Testing (if necessary)
Measure different windings (high voltage, medium voltage, low voltage) or each bushing separately, and conduct comparative analysis to ensure the insulation status of all parts.
Evaluation Criteria (Reference)
Insulation resistance ≥ 1000 MΩ (excellent)
500 MΩ ≤ Insulation resistance < 1000 MΩ (good)
100 MΩ ≤ Insulation resistance < 500 MΩ
Insulation resistance < 100 MΩ
*These comprehensive tests ensure that each transformer meets performance standards and operates reliably under various conditions.
Earth Transformer Routine Test

Application

Suitable for utility substations and industrial power systems requiring high-impedance grounding to limit earth fault currents and improve protection coordination in 11kV networks.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Transformers Packaging (1)
Transformers Packaging (1)
Transformers Packaging (2)
Transformers Packaging (2)
Transformers Packaging (3)
Transformers Packaging (3)
Transformers Packaging (4)
Transformers Packaging (4)
Transformers Packaging (5)
Transformers Packaging (5)
Transformers Packaging (6)
Transformers Packaging (6)
Transformers Packaging (7)
Transformers Packaging (7)
Transformers Packaging (8)
Transformers Packaging (8)

Related Products

FAQ From Customers

What is a Transformer?
A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
What are the main uses of a transformer?
The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
Do you have UL listed?
Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.