Mining Cable

(N)TSCGECECWOU 8.7/15kV and 12/20kV ZH Cable
The (N)TSCGECECWOU 8.7/15kV and 12/20kV ZH cable is a flexible medium voltage power cable designed and manufactured to DIN VDE 0250 standards. Engineered for demanding mining, tunneling, and mobile equipment applications, it features EPR insulation, a halogen-free flame-retardant sheath, and a concentric copper conductor to ensure exceptional mechanical strength, EMC protection, and resistance to oil, moisture, and fire. With a robust PUR outer sheath and halogen-free materials, this cable provides high flexibility and durability for reeling and trailing systems in harsh industrial environments, making it ideal for tunnel boring machines, mining conveyors, and other heavy-duty energy supply applications.
NTSCGECECWOU 3.6/6kV and 6/10kV Cable
The NTSCGECECWOU 3.6/6kV and 6/10kV cable is a flexible medium voltage power cable manufactured to VDE 0250 Part 813 standards, designed for reeling and trailing applications in mining, tunneling, and other demanding industrial environments. Constructed with Class 5 tinned copper conductors, EPR insulation, and a robust halogen-free sheath, it delivers exceptional mechanical strength, flame retardancy, oil resistance, and flexibility. Its copper wire screen ensures EMC protection, while the rugged sheath withstands extreme temperatures, making it suitable for both indoor and outdoor installations in harsh conditions.
NTSCGECECWOU 8.7/15kV and 12/20kV Cable
NTSCGECECWOU 8.7/15kV and 12/20kV cable is a flexible medium voltage power cable manufactured according to DIN VDE 0250 standards, engineered for heavy-duty energy supply in mining, tunneling, and mobile equipment applications. Featuring Class 5 tinned copper conductors, EPR insulation, a halogen-free flame-retardant sheath, and concentric copper conductors for EMC protection, it ensures outstanding mechanical strength, oil and moisture resistance, and fire safety. Designed for reeling drum systems and mobile machinery, it is ideal for both indoor and outdoor use in harsh, demanding environments.
(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable
The (N)TSCGECEWOU 3.6/6kV and 6/10kV ATB cable is a flexible medium voltage power cable designed according to VDE standards for heavy-duty applications in mining, tunneling, and dynamic machinery such as tunnel boring machines (ATB). It features Class 5 tinned copper conductors, EPR insulation, halogen-free flame-retardant sheath, and an anti-torsion braid for stability in reeling and trailing operations. With excellent mechanical strength, oil resistance, and abrasion resistance, this cable ensures reliable performance in harsh industrial environments, both indoors and outdoors.
(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable
The (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB cable is a flexible high-voltage power cable designed for tunnel boring machines and other heavy-duty mobile equipment operating under high mechanical stress. Built to VDE standards, it features Class 5 tinned copper conductors, EPR insulation, halogen-free flame-retardant sheath, and a polyester anti-torsion braid for exceptional performance in reeling and trailing applications. With abrasion resistance, oil resistance, and outdoor durability, this cable ensures reliable high-voltage power transmission in demanding mining and tunneling environments.
(N)TSCGECEWOU 1.8/3kV, 3.6/6kV and 6/10kV ATB (Ground Check Conductor)
The (N)TSCGECEWOU 1.8/3kV, 3.6/6kV and 6/10kV ATB cable (Ground Check Conductor) is a medium voltage flexible power cable designed for mining and heavy-duty machinery. It features ground detection conductor, Class 5 tinned copper conductors, EPR insulation, halogen-free flame-retardant sheath, and copper wire braid shielding, ensuring high abrasion resistance, oil resistance, and mechanical durability. This cable is built according to VDE 0250 standards for reliable performance in extreme indoor and outdoor industrial environments under continuous drag and torsion.
(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor)
The (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB cable (Ground Check Conductor) is a high-voltage flexible mining cable designed for heavy mobile equipment such as excavators, loaders, and drills in open-pit mines. It features a ground detection conductor, Class 5 tinned copper conductors, EPR insulation, halogen-free flame-retardant sheath, and copper wire braided shielding. Engineered according to VDE 0250 standards, this cable offers exceptional abrasion resistance, oil resistance, and mechanical strength, suitable for harsh indoor and outdoor environments with continuous drag and torsion.
(N)TSCGECEWOU - 3.6/6kV, 6/10kV, 8.7/15kV and 12/20kV Submersible Cable
The (N)TSCGECEWOU 3.6/6kV, 6/10kV, 8.7/15kV, and 12/20kV Submersible Cable is a medium voltage flexible cable engineered for long-term underwater and humid environment applications. It features Class 5 tinned copper conductors, EPR insulation, halogen-free flame-retardant waterproof sheath, and copper wire braided shielding. Compliant with VDE 0250 standards, it delivers outstanding water resistance (up to 300m depth), mechanical strength, and oil & abrasion resistance, making it ideal for mining, dredging, pumps, and marine equipment.
NTSCGECEWOU 3.6/6kV, 6/10kV, 8.7/15kV and 12/20kV Cable
The (N)TSCGECEWOU 3.6/6kV, 6/10kV, 8.7/15kV, and 12/20kV Cable is a medium voltage flexible power cable designed according to DIN VDE 0250 standards. It features Class 5 tinned copper conductors, EPR rubber insulation, semi-conductive layers, halogen-free flame-retardant rubber sheath, and copper wire braided shielding for enhanced mechanical strength, oil resistance, and moisture protection. This cable is ideal for mining, tunnel construction, and heavy mobile machinery, offering excellent abrasion resistance and durability in demanding environments.Why Choose Us
As a trusted partner in energy savings and the development of green energy solutions, NPC
Electric has played a pioneering role in the development of national smart grids across
multiple regions.

Project Experience
With years of experience in power transmission and distribution, NPC Electric has become
a trusted name in the manufacturing of cables and transformers. We’ve successfully
served international EPC companies such as Elecnor, Cobra, and Equans in Latin America,
Africa, and Southeast Asia.We have provided the 132kV Power Transformer,Pad Mounted
Transformer and Earth Transformer.

Technical Support
NPC Electric’s skilled engineers offer full-cycle support—from design consultation and
technical drawings to on-site guidance and after-sales service—ensuring peace of mind at
every stage of the project.
We have a technical team of over 60 members and more than 100 after-sales engineers,
ready to assist customers with installation and on-site support.
Till now, we have provided professional engineering services in countries such as
Mongolia, Honduras, Peru, and Rwanda. Our services include winding resistance testing,
oil testing, and installation support.

Quality Control
NPC Electric uses high-quality raw materials and advanced production processes,
supported by strict quality control systems. Our products meet or exceed international
standards such as IEC, UL, and ISO, ensuring safety, reliability, and long service life.
All our cables are subject to third-party laboratory testing—such as by SGS, DNV, or
witnessed directly by customers—to ensure compliance and performance.

Efficient Logistics & Timely Delivery
With over 4,200 sqm of warehouse space and a strategic in China, we guarantee timely
delivery and flexible logistics to meet tight project schedules globally.We have the
professional team to assitance the customer to ship the production, we can do
EXW,CIF,FOB,FCA,CIP or any customer request terms.
Technical Advantages
● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.