100kVA Completely self-protected(CSP) Single Phase Pole Mounted Transformer

100kVA Completely Self-Protected (CSP) Single Phase Pole Mounted Transformer is a highly efficient and reliable solution designed for single-phase power distribution in residential, commercial, and light industrial applications. It features integrated self-protection systems, including overload, short-circuit, and over-voltage protection, ensuring automatic disconnection in the event of faults to safeguard both the transformer and connected equipment. With its pole-mounted design, it offers space-saving installation and is suitable for both urban and rural environments. This transformer delivers high operational efficiency with minimal energy loss and is built to withstand harsh weather conditions, ensuring long-lasting and reliable performance. It is the ideal choice for providing safe and stable single-phase power in diverse applications.
Primary Voltage Ratings 2.4-34.5kV
Secondary Voltage Ratings 480-240/240-120 or customized
H.V. Tap Range ± 2×2.5% HV taps or others
Type Completely self-protected(CSP) Type
BIL 30-150kV
Standards IEEE, ANSI, IEC, CSA, NEMA, UL
Application Residential, commercial and remote electrical power distribution systems
Power Rating 100kVA
Certificate CE, ISO
Cooling Method ONAN
Oil Minerial Oil or FR3
Opeartion Step Down
Technical Specifications
Customization Optional
Packing and Shipping
Manufacturer Test
Routine Testing
Application

Technical Specifications

100kVA Completely self-protected(CSP) Single Phase Pole Mounted Transformer
Technical Specifications
Accessories
Rated Power 100 kVA
Rating Primary Voltage 12.4-34.5kV 
Secondary Voltage 480-240V
240-120V
277V
Customized
Frequency 50/60Hz
Vector Group Ii0,Ii6
Winding Material Aluminum/Copper
Efficiency As IEEE,Doe 2016,CAS Std or Customized
Impedance Voltage Nominal 2% or Customized 1.1-5.75% 
Altitude ≤1,000m or Customized
Color ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized etc
Tank material Mild Steel, 304 Stainless Steel
Insulating Oil Weight 94 kg
Total Weight 530 kg
Outline Dimensions(W×D×H) 770×965×1135 (mm)
Lifting Lug 
Tap Changer
Pressure Relief Valve
Tank Cover and clamp
L.V Bushing
HV Bushing
Ground Strap
Nameplate
Non-PCB decal
High Voltage Warning Signs
Support lug
Oil fill valve
Surge arrester
Secondary breaker
Weak link

Customization Optional

100kVA Completely self-protected(CSP) Single Phase Pole Mounted Transformer
NPC ELECTRIC's Completely Self-Protected (CSP) Single-Phase Pole-Mounted Transformers offer a range of customizable features to meet diverse operational needs.
The optional specifications for the 100kVA Completely Self-Protected (CSP) Single Phase Pole Mounted Transformer offer a variety of customization options to meet specific operational and environmental needs. These options include adjustable input voltage levels, such as 11kV, 13.8kV, or other regional standards, ensuring compatibility with different utility grid systems. The output voltage can also be customized, typically offering 230V or 400V configurations, depending on the specific power requirements of the application.
For enhanced protection, the transformer can be equipped with surge protection devices to safeguard against voltage spikes and over-temperature monitoring systems to ensure safe operation under high-temperature conditions. Remote monitoring capabilities can be added, allowing operators to track performance, detect faults, and manage the transformer remotely for improved efficiency and maintenance.
In challenging environmental conditions, additional features such as corrosion-resistant coatings or weatherproof enclosures can be selected to protect the transformer from harsh weather, moisture, and contaminants. High-grade insulation materials may also be chosen to increase reliability and performance, especially in areas with extreme weather or industrial pollution.
These customizable options make the 100kVA CSP Single Phase Pole Mounted Transformer highly adaptable for diverse applications, ensuring reliable, safe, and long-lasting power distribution in various settings.

Packing and Shipping

100kVA Completely self-protected(CSP) Single Phase Pole Mounted Transformer
NPC ELECTRIC single-phase transformers are designed to be securely packaged for sea freight transport, ensuring safe delivery across long distances.
For this purpose, the packing of the 100kVA Completely Self-Protected (CSP) Single Phase Pole Mounted Transformer is a meticulous process aimed at safeguarding the product throughout its journey from the factory to the installation site.
The transformer is first enveloped in a high-grade anti-static and moisture-resistant plastic film. This film not only shields the transformer from moisture, which could cause corrosion and electrical malfunctions, but also prevents the accumulation of static electricity that might damage sensitive components. After that, a layer of soft, high-density foam padding is carefully wrapped around the transformer. This foam acts as a shock absorber, protecting the unit from impacts and vibrations during handling and transportation. Special attention is given to the protruding parts and vulnerable areas, where additional foam is added for extra protection.
The foam-wrapped transformer is then placed into a custom-fabricated wooden box. The interior of the box is lined with a layer of rubber or felt to further dampen vibrations. The box is designed to fit the transformer precisely, with custom-cut compartments and supports to hold the unit firmly in place. Reinforcing bars are installed on the corners and edges of the box to enhance its structural integrity and prevent it from being crushed or damaged.
On the exterior of the wooden box, clear and prominent labels are affixed. These labels include handling instructions such as "Fragile", "This Side Up", and "Keep Dry". Product information labels display details such as the transformer's model number, capacity (100kVA), weight, and dimensions. There are also warning signs indicating the presence of high-voltage components and safety precautions.
The choice of transport mode depends on the destination and delivery time requirements. For local or regional deliveries, trucks are typically used due to their flexibility and relatively short transit times. The trucks are equipped with shock-absorbing suspension systems to minimize vibrations during the journey. For long-distance or international shipments, a combination of sea freight and land transport may be employed. Sea freight is cost-effective for large and heavy items like transformers, while land transport is used for the final leg of the journey to the installation site.
During loading, the transformer is carefully lifted using appropriate lifting equipment such as cranes or forklifts. Once loaded onto the transport vehicle, the wooden box is secured using heavy-duty straps and chains. The straps are tightened to ensure that the box remains stable and does not shift during transit. Additional bracing materials may be used to further secure the box in place, especially in the case of rough roads or long-distance travel.
100kVA Completely self-protected(CSP) Single Phase Pole Mounted transformer package
100kVA Completely self-protected(CSP) Single Phase Pole Mounted transformer package mini
32
32 years of industry experience

Manufacturer Test

100kVA Completely self-protected(CSP) Single Phase Pole Mounted Transformer
100kVA Completely self-protected(CSP) Single Phase Pole Mounted transformer  Progress Test

Progress Test

NPC Electric manufactures pad-mounted transformers have the strict quality control. The progress test for the 100kVA Completely Self-Protected (CSP) Single Phase Pole Mounted Transformer involves a series of checks conducted during the manufacturing process to ensure the transformer adheres to all technical specifications and safety standards. Key aspects of the test include verifying the input and output voltage, checking load performance, and ensuring the functionality of the transformer’s built-in protection mechanisms, such as overload, short-circuit, and over-voltage protection. Insulation resistance and dielectric strength tests are also performed to confirm the transformer's electrical integrity. Additionally, the self-protection system is tested to ensure it can automatically disconnect the transformer in case of faults, safeguarding both the transformer and the system. These progress tests help identify potential issues early, ensuring the transformer is ready for the final factory acceptance test.

100kVA Completely self-protected(CSP) Single Phase Pole Mounted transformer   Design Tests

Design Tests

All transformer will be test after finished the production, test items as below:
♦ Insulation Power Factor
♦ Ratio, Polarity, and Phase Relation
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Polarity, 1-Ph 
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Applied Voltage
♦ Induced Voltage
♦ Lightning Impulse
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise
♦ Dielectric Withstand (Hipot)

China NPC ELECTRIC

Transformer Factory Acceptance Test

NPC Electric will tests made for quality control by the manufacturer on every device or representative samples, or on parts or materials as required, to verify during production that the product meets the design specifications.

The factory acceptance test for the 100kVA fully self-protected (CSP) single-phase pole-mounted transformer is a key link in ensuring product quality and performance compliance.

The test is comprehensive and rigorous, with electrical performance testing as the focus. The ratio test accurately verifies the accuracy of the transformer voltage conversion, the no-load test and short-circuit test measure the no-load loss and load loss respectively to evaluate its operating efficiency and energy saving, and the insulation resistance, dielectric loss factor and partial discharge test are used to detect insulation performance to ensure safe operation.

In terms of mechanical performance, the appearance, size, structural strength and firmness of component connections of the transformer were carefully checked to ensure that it can adapt to the outdoor pole installation and operation environment.

In addition, a protection function test was carried out to verify the reliability of its self-protection mechanism.

Each test strictly follows the relevant standards and specifications, and based on detailed test data and result analysis, a comprehensive judgment is made as to whether the transformer meets the factory requirements, laying the foundation for its subsequent stable and reliable operation.

Routine Test - On load Loss Test

Purpose of Testing
The purpose of On-load Loss Test is to measure the active power loss of the transformer under rated voltage and rated load, evaluate its energy efficiency level and design compliance, and provide a basis for energy consumption calculation and performance optimization during operation.
Testing Equipment
Power transformer test system (e.g. OMICRON, ISA, Tettex, Vanguard, etc.)
Voltage source and current source (usually rated voltage, or adjusted according to the test standard, such as 10 KV, 20 KV, 35 KV, etc.)
Temperature and humidity meter (used to record ambient temperature and humidity for correction of test data)
Pre-Test Preparation
Disconnect the transformer high voltage, low voltage and neutral power supply to ensure that the equipment is properly grounded and safely discharged.
The test environment should be dry and rainless, with a relative humidity of less than 75% and a recommended temperature range of 20–30°C.
Test Progress
Connect the Test Instrument:
Connect the test equipment to the appropriate terminals of the device under test and ensure that all wiring is correct and the device is well grounded.
Apply Test Voltage:
Apply the specified test voltage at the rated frequency and adjust the low voltage side to maintain the rated current (or specified current).
Measure and Record
Start the test and record the following parameters:
On-Load Loss Power
Input Power and Output Power
Current
Voltage
Temperature (temperature rise or winding temperature)
Ambient temperature and humidity during the test
Temperature Correction
The measured loss data is corrected based on a reference temperature (usually 20°C) to ensure the accuracy of the results.
Repeat Testing (if necessary)
Test different tap positions (Tap Changer) and record and compare the load loss data of each tap point.
Evaluation Criteria (Reference)
Evaluate the test results based on the equipment type and manufacturer requirements. If the load losses are low and the efficiency is high, it is considered "normal". If the load losses are too high or the efficiency is low, further inspection or corrective action is required.
*These comprehensive tests ensure that each transformer meets performance standards and operates reliably under various conditions.
100kVA Completely self-protected(CSP) Single Phase Pole Mounted transformer Roution Test

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Transformers Packaging (1)
Transformers Packaging (1)
Transformers Packaging (2)
Transformers Packaging (2)
Transformers Packaging (3)
Transformers Packaging (3)
Transformers Packaging (4)
Transformers Packaging (4)
Transformers Packaging (5)
Transformers Packaging (5)
Transformers Packaging (6)
Transformers Packaging (6)
Transformers Packaging (7)
Transformers Packaging (7)
Transformers Packaging (8)
Transformers Packaging (8)

Related Products

FAQ From Customers

What is a Transformer?
A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
What are the main uses of a transformer?
The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
Do you have UL listed?
Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.

Welcome your inquiry