42MVA 220kV Three Phase Oil Filled Transformer for Substation
- Primary Voltage Ratings 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2, 33 or others
- Secondary Voltage Ratings 480/277V, 400/230V, 380/220V or customized
- H.V. Tap Range ± 2×2.5% HV taps or others
- Type Oil immersed transformer
- BIL 220kV
- Standards IEEE, ANSI, NEMA, IEC, CE
- Application transmission substations, step-down grid, backbone power grid
- Power Rating 42MVA
- Certificate UL, CESI, IEEE
- Cooling Method ONAN, ONAN/ONAF, KNAN, KNAN/KNAF
- Oil Mineral Oil or FR3
- Opeartion Step Down & Step Up
Technical Specifications
| Rated Power | 42 MVA | |
| Rating Primary Voltage | 2.4 - 220kV | |
| Secondary Voltage | 480/277V 400/230V 380/220V Customized |
|
| Frequency | 50/60Hz | |
| Vector Group | Dyn11, Yyn0, Dyn5 | |
| Winding Material | Aluminum/Copper | |
| Efficiency | As IEEE, Doe 2016, CAS Std or Customized | |
| Impedance Voltage | Nominal 2% or Customized 1.1 - 5.75% | |
| Altitude | ≤1,000m or Customized | |
| Color | ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc | |
| Tank material | Mild Steel, 304 Stainless Steel | |
| HV Bushing |
| LV Bushing |
| Tap changer |
| Oil level gauge |
| Oil temperature indicator |
| Pressure relief device |
| Pressure vacuum gauge |
| Lifting hook for complete transformer |
| Name plate |
| Radiators |
| Oil upper filtering valve |
| Oil drain valve with 3/8" sampler |
Customization Optional
Packing and Shipping
Immediately after FAT approval and client sign-off, the transformer is vacuum-dehydrated to below 1 mbar and filled with ultra-dry nitrogen to 0.03–0.04 MPa positive pressure, effectively isolating insulation oil from air and moisture. All 220kV porcelain bushings, neutral bushings, conservator, detachable radiators, OLTC drive mechanism, cooling fans, Buchholz relay, and instruments are professionally dismantled, shock-proof packed in individual IPPC-fumigated plywood crates with multi-layer foam, desiccant bags, and dedicated shock/tilt indicators.
The main tank (gross weight approx. 85–95 tons) is welded onto a reinforced heavy-duty steel skid with 20 certified lashing points and four lifting lugs tested to 150% load. The body is then fully enclosed in a robust sealed wooden/steel composite crate using 30 mm marine plywood and 120×120 mm steel framing, double-wrapped with a waterproof membrane and aluminium-foil barrier. External surfaces carry clear bilingual markings (“42MVA 220kV Three Phase Oil Filled Transformer”), centre-of-gravity, lifting instructions, “No Hook”, “Keep Dry”, and IMO labels. Ten high-precision digital shock recorders and GPS real-time tilt monitors are installed for full traceability.
Transportation employs only licensed ultra-heavy haulage solutions: inland via 24–32 axle hydraulic modular trailers with route survey and escort; ocean freight as break-bulk under-deck or on DNV 2.7-1 certified 80ft heavy-lift flat-racks secured with Φ36 mm wire ropes and classification-society-approved lashing plans. Complete documentation—including detailed packing list, Form A/E origin certificate, fumigation certificate, nitrogen pressure report, insurance policy (110% value), and installation manual—is shipped together. These rigorous measures guarantee every 42MVA 220kV Three Phase Oil Filled Transformer reaches site in perfect condition, ready for immediate erection and commissioning.
Manufacturer Test
Progress Test
The 42MVA 220kV Three Phase Oil Filled Transformer is subject to strict in-process Progress Tests at critical stages to guarantee exceptional quality:
- Active part completion: winding DC resistance at every tap, insulation resistance between HV-LV-core (PI ≥ 3.0), core earth current (<80 mA), and no-load loss preliminary measurement.
- Pre-vacuum stage: turns ratio & polarity at all taps (tolerance ≤ ±0.5%), vector group verification, zero-sequence impedance, and winding dielectric power factor.
- Post-processing stage (after 130°C vapor-phase drying and hot oil circulation): final insulation resistance (>10,000 MΩ), tanδ ≤ 0.0030 (20°C), partial discharge <10 pC at 1.5Um/√3, and oil dielectric strength >75 kV/2.5 mm.
- Final assembly: 24-hour oil static leakage test and 0.45 bar overpressure/vacuum tightness test for 24 hours each.
All test data are documented and submitted for client or third-party witness approval prior to Factory Acceptance Test, ensuring every 42MVA 220kV Three Phase Oil Filled Transformer meets the highest 220 kV transmission standards.
Design Tests
All transformer will be test after finished the production, test items as below:
♦ Insulation Power Factor
♦ Ratio, Polarity, and Phase Relation
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Polarity, 1-Ph / Phase Relation, 3-Ph (Rated Voltage)
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Applied Voltage
♦ Induced Voltage
♦ Lightning Impulse
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise
♦ Dielectric Withstand (Hipot)
Transformer Factory Acceptance Test
Performed according to IEC 60076 series and client technical agreement, fully witnessed:
- Measurement of winding resistance at all OLTC positions (corrected to 75 °C)
- Ratio, polarity and phase displacement test at rated, +max and -max tap (tolerance ≤ ±0.5%)
- Vector group verification and magnetic balance test
- No-load loss & no-load current at 90 %, 100 %, 110 % rated voltage
- Load loss and impedance voltage at 75 °C, rated current on principal tap
- Zero-sequence impedance on all three phases
- Applied potential test (separate source AC withstand)
- Induced AC withstand test with PD monitoring (<10 pC at 1.5Um/√3, <5 pC at Um/√3)
- Lightning impulse full wave and chopped wave (950 kV peak on 220 kV side)
Complete FAT report with raw data and calibration certificates is signed off, ensuring the 42MVA 220kV Three Phase Oil Filled Transformer is 100 % qualified for immediate shipment and long-term reliable operation in 220 kV transmission networks.
Routine Test - Lightning Impulse
Check all terminals and connections to ensure they are secure and free of contamination.
Perform the test under suitable environmental conditions: relative humidity less than 75%, temperature between 20-30°C, no rain.
Current waveform Impedance
Reaction voltage waveform
Ambient temperature and humidity during testing
The voltage waveform meets the standard requirements, and the equipment does not have abnormal discharge or local breakdown: good
Obvious damage or non-standard waveform during the test: Further inspection or corrective measures are required
Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What is a Transformer?A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
-
What are the main uses of a transformer?The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
-
Do you have UL listed?Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.