42MVA 220kV Three Phase Oil Filled Transformer for Substation

The 42MVA 220kV Three Phase Oil Filled Transformer is specifically engineered for high-voltage transmission substations and utility grid applications. Featuring 99.9% electrolytic copper windings, advanced ONAN/ONAF cooling, and ±8×1.25% on-load tap changer, it ensures ultra-low no-load and load losses (SZ13 series available). Fully compliant with IEC 60076, GB/T 6451, and ANSI/IEEE standards, it successfully passes 460 kV lightning impulse, PD level below 10 pC, and induced test at 1.5Um/√3. Robust corrugated tank and conservator design provide excellent thermal and mechanical performance in extreme climates. Ideal for 220/33kV, 220/11kV, or 220/6.6kV step-down configurations. Vacuum oil processing and nitrogen blanketing guarantee long-term reliability and 35+ year service life. Trusted by national grids worldwide. Contact us for datasheet, pricing, and customization options.
Primary Voltage Ratings 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2, 33 or others
Secondary Voltage Ratings 480/277V, 400/230V, 380/220V or customized
H.V. Tap Range ± 2×2.5% HV taps or others
Type Oil immersed transformer
BIL 220kV
Standards IEEE, ANSI, NEMA, IEC, CE
Application transmission substations, step-down grid, backbone power grid
Power Rating 42MVA
Certificate UL, CESI, IEEE
Cooling Method ONAN, ONAN/ONAF, KNAN, KNAN/KNAF
Oil Mineral Oil or FR3
Opeartion Step Down & Step Up
Technical Specifications
Customization Optional
Packing and Shipping
Manufacturer Test
Routine Testing
Application

Technical Specifications

42MVA 220kV Three Phase Oil Filled Transformer for Substation
Technical Specifications
Accessories
Rated Power 42 MVA
Rating Primary Voltage 2.4 - 220kV
Secondary Voltage 480/277V
400/230V
380/220V
Customized
Frequency 50/60Hz
Vector Group Dyn11, Yyn0, Dyn5
Winding Material Aluminum/Copper
Efficiency As IEEE, Doe 2016, CAS Std or Customized
Impedance Voltage Nominal 2% or Customized 1.1 - 5.75% 
Altitude ≤1,000m or Customized
Color ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc
Tank material Mild Steel, 304 Stainless Steel
HV Bushing
LV Bushing
Tap changer
Oil level gauge
Oil temperature indicator
Pressure relief device
Pressure vacuum gauge
Lifting hook for complete transformer
Name plate
Radiators
Oil upper filtering valve
Oil drain valve with 3/8" sampler

Customization Optional

42MVA 220kV Three Phase Oil Filled Transformer for Substation
The 42MVA 220kV Three Phase Oil Filled Transformer offers comprehensive customization to meet specific grid and substation requirements. Clients can choose copper or aluminum windings, ONAN, ONAF, or ODAF cooling methods, tap range of ±8×1.25%, ±10×1%, or special dual-ratio OLTC, and vector groups such as YNd11, Dyn11, or custom connections. Voltage combinations include 220±8×1.25%/33kV, 220/110/11kV tertiary, 220/35kV, or non-standard configurations. Impedance can be adjusted from 10% to 20%, with options for ultra-low-loss SZ13/SZ14 series, noise levels below 65 dB, or high-efficiency amorphous core designs.
Additional features include built-in current/voltage transformers, forced-air fan auto-control systems, online DGA and oil filtration interfaces, fiber-optic winding temperature monitoring, sudden pressure relay with trip/alarm, and full SCADA/RTU integration. Special adaptations cover high-altitude operation (>4000 m), seismic qualification up to 0.5g, extreme temperature (-50°C to +50°C), and heavy anti-corrosion C5-M/C5X painting. All customizations remain fully compliant with IEC 60076 and are supported by type/special test reports, ensuring seamless integration into any 220kV transmission project worldwide.

Packing and Shipping

42MVA 220kV Three Phase Oil Filled Transformer for Substation
To ensure the 42MVA 220kV Three Phase Oil Filled Transformer arrives at any 220kV substation worldwide without damage, we strictly execute the highest international heavy-transformer transportation standards (IEC 62271-207, IMO/ILO/UN packing codes, and CCS/DNV-GL guidelines).
Immediately after FAT approval and client sign-off, the transformer is vacuum-dehydrated to below 1 mbar and filled with ultra-dry nitrogen to 0.03–0.04 MPa positive pressure, effectively isolating insulation oil from air and moisture. All 220kV porcelain bushings, neutral bushings, conservator, detachable radiators, OLTC drive mechanism, cooling fans, Buchholz relay, and instruments are professionally dismantled, shock-proof packed in individual IPPC-fumigated plywood crates with multi-layer foam, desiccant bags, and dedicated shock/tilt indicators.
The main tank (gross weight approx. 85–95 tons) is welded onto a reinforced heavy-duty steel skid with 20 certified lashing points and four lifting lugs tested to 150% load. The body is then fully enclosed in a robust sealed wooden/steel composite crate using 30 mm marine plywood and 120×120 mm steel framing, double-wrapped with a waterproof membrane and aluminium-foil barrier. External surfaces carry clear bilingual markings (“42MVA 220kV Three Phase Oil Filled Transformer”), centre-of-gravity, lifting instructions, “No Hook”, “Keep Dry”, and IMO labels. Ten high-precision digital shock recorders and GPS real-time tilt monitors are installed for full traceability.
Transportation employs only licensed ultra-heavy haulage solutions: inland via 24–32 axle hydraulic modular trailers with route survey and escort; ocean freight as break-bulk under-deck or on DNV 2.7-1 certified 80ft heavy-lift flat-racks secured with Φ36 mm wire ropes and classification-society-approved lashing plans. Complete documentation—including detailed packing list, Form A/E origin certificate, fumigation certificate, nitrogen pressure report, insurance policy (110% value), and installation manual—is shipped together. These rigorous measures guarantee every 42MVA 220kV Three Phase Oil Filled Transformer reaches site in perfect condition, ready for immediate erection and commissioning.
Oil Immersed Transformer package
Oil Immersed Transformer package mini
32
32 years of industry experience

Manufacturer Test

42MVA 220kV Three Phase Oil Filled Transformer for Substation
Oil Immersed Transformer Progress Test

Progress Test

The 42MVA 220kV Three Phase Oil Filled Transformer is subject to strict in-process Progress Tests at critical stages to guarantee exceptional quality:

  1. Active part completion: winding DC resistance at every tap, insulation resistance between HV-LV-core (PI ≥ 3.0), core earth current (<80 mA), and no-load loss preliminary measurement.
  2. Pre-vacuum stage: turns ratio & polarity at all taps (tolerance ≤ ±0.5%), vector group verification, zero-sequence impedance, and winding dielectric power factor.
  3. Post-processing stage (after 130°C vapor-phase drying and hot oil circulation): final insulation resistance (>10,000 MΩ), tanδ ≤ 0.0030 (20°C), partial discharge <10 pC at 1.5Um/√3, and oil dielectric strength >75 kV/2.5 mm.
  4. Final assembly: 24-hour oil static leakage test and 0.45 bar overpressure/vacuum tightness test for 24 hours each.

All test data are documented and submitted for client or third-party witness approval prior to Factory Acceptance Test, ensuring every 42MVA 220kV Three Phase Oil Filled Transformer meets the highest 220 kV transmission standards.

Oil Immersed Transformer  Design Tests

Design Tests

All transformer will be test after finished the production, test items as below:
♦ Insulation Power Factor
♦ Ratio, Polarity, and Phase Relation
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Polarity, 1-Ph / Phase Relation, 3-Ph (Rated Voltage)
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Applied Voltage
♦ Induced Voltage
♦ Lightning Impulse
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise
♦ Dielectric Withstand (Hipot)

China NPC ELECTRIC

Transformer Factory Acceptance Test

Performed according to IEC 60076 series and client technical agreement, fully witnessed:

  1. Measurement of winding resistance at all OLTC positions (corrected to 75 °C)
  2. Ratio, polarity and phase displacement test at rated, +max and -max tap (tolerance ≤ ±0.5%)
  3. Vector group verification and magnetic balance test
  4. No-load loss & no-load current at 90 %, 100 %, 110 % rated voltage
  5. Load loss and impedance voltage at 75 °C, rated current on principal tap
  6. Zero-sequence impedance on all three phases
  7. Applied potential test (separate source AC withstand)
  8. Induced AC withstand test with PD monitoring (<10 pC at 1.5Um/√3, <5 pC at Um/√3)
  9. Lightning impulse full wave and chopped wave (950 kV peak on 220 kV side)

Complete FAT report with raw data and calibration certificates is signed off, ensuring the 42MVA 220kV Three Phase Oil Filled Transformer is 100 % qualified for immediate shipment and long-term reliable operation in 220 kV transmission networks.

Routine Test - Lightning Impulse

Purpose of Testing
The purpose of the lightning impulse test is to simulate the performance of the equipment when it is subjected to lightning or high voltage transient pulses, so as to evaluate its lightning resistance and insulation performance.
Testing Equipment
Lightning Impulse Tester. Usually a high voltage DC power supply, used to simulate lightning impulse waves. The voltage range can be adjusted according to the test standards and equipment requirements. Common voltages are 200 kV, 500 kV or higher. The specific voltage is customized according to customer requirements.
Pre-Test Preparation
Disconnect the device from the power supply and ensure that the device is properly grounded and discharged.
Check all terminals and connections to ensure they are secure and free of contamination.
Perform the test under suitable environmental conditions: relative humidity less than 75%, temperature between 20-30°C, no rain.
Test Progress
Connect the Test Instrument: Connect the lightning impulse test equipment to the high-voltage terminal or bushing of the device under test. Apply Test Voltage: According to the rated voltage of the equipment and the test standard, select the appropriate test voltage.
Measure and Record
Start the test and record the following parameters: Applied impulse voltage (kV)
Current waveform Impedance
Reaction voltage waveform
Ambient temperature and humidity during testing
Temperature Correction
The measured test data is temperature corrected according to the ambient temperature during the test, usually with a reference temperature of 20°C, to ensure the accuracy of the test results.
Repeat Testing (if necessary)
Repeated testing of different windings (high voltage, medium voltage, low voltage) or bushings under different test conditions ensures that the insulation performance of each part meets the standards.
Evaluation Criteria (Reference)
The lightning impulse test did not produce breakdown or irreversible damage: qualified
The voltage waveform meets the standard requirements, and the equipment does not have abnormal discharge or local breakdown: good
Obvious damage or non-standard waveform during the test: Further inspection or corrective measures are required
*These comprehensive tests ensure that each transformer meets performance standards and operates reliably under various conditions.
Oil Immersed Transformer Routine Test

Application

220kV transmission substations, step-down to 110kV/33kV grid, national backbone power grid interconnection, large-scale renewable energy integration (wind/solar farms), heavy industrial complexes (steel mills, petrochemical plants), urban high-voltage ring network supply, pumped-storage hydropower stations, railway traction substations (25kV feeding)

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Transformers Packaging (1)
Transformers Packaging (1)
Transformers Packaging (2)
Transformers Packaging (2)
Transformers Packaging (3)
Transformers Packaging (3)
Transformers Packaging (4)
Transformers Packaging (4)
Transformers Packaging (5)
Transformers Packaging (5)
Transformers Packaging (6)
Transformers Packaging (6)
Transformers Packaging (7)
Transformers Packaging (7)
Transformers Packaging (8)
Transformers Packaging (8)

Related Products

FAQ From Customers

What is a Transformer?
A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
What are the main uses of a transformer?
The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
Do you have UL listed?
Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion